50L - Foam Fire Extinguisher


- Model :DKPK-50KK
- Extinguisher Type :Continuous Pressure
- Capacity :50 Kg
- Extinguishing Agent :AFF Foam
- Propellant Type :N2 (Nitrogen)
- Test Pressure(kg/cm²) :50 BAR
- Operating Pressure(kg/cm²) :18 BAR
- Operating Temperature :0°C / +60°C
- Discharge Time :55 Seconds
- Spray Distance :7 Meters
- Fire Class :34A 275B
- Height(mm) :1150 mm
- Width(mm) :480 mm
- Depth(mm) :450 mm
- Sheet Thickness(mm) :2.5 mm



Effective in Class A and B fires. When used, the foam covers the burning material, cutting off the oxygen and extinguishing the fire. Due to this property, it is particularly effective in gasoline/diesel fires and is the preferred fire extinguisher in fuel terminals and filling stations, or in thinner/paint warehouses. Since it is water-based, it should definitely not be used for electrical fires! Given that a significant portion of fires in our country originate from electrical panels and transformers, it is extremely dangerous to have only this type of extinguisher present in such environments.
Fire extinguishing foam consists of bubbles formed under pressure from foam concentrate, water, and air. Foam Formula: Foam concentrate + Water + Nitrogen.
Low-expansion foam extinguishing systems can be used in special fire situations involving flammable and combustible liquids, such as tanker loading and petroleum stations. The foam extinguisher discharges foam bubbles onto the liquid surface. This creates a layer of foam that cools and suppresses the fire on the flammable liquid surface. High-expansion foams are used in areas where the goal is to fill the space with foam and prevent the fire from coming into contact with air. A good foam fire extinguisher should have properties such as durability, adhesiveness, heat resistance, steam retention, preventing re-ignition, and effective fire suppression.
7114(DC-04) Quality DKP Special Deep Drawing Steel
After the welding process, it undergoes a test where it is exposed to 50 Bar pressure on a testing machine. Our devices' steel body undergoes a 50 BAR hydrostatic pressure test. The trigger mechanism, which ensures controlled operation of our devices, is CE certified. The trigger mechanism has a safety valve that balances the gas pressure against sudden changes in pressure due to drops, shocks, or similar situations. After body welding, the device undergoes leak-tightness tests in the testing machine. Our product, which easily passes the extinguishing tests conducted by the Turkish Standards Institute (TSE) and the Ministry of Industry, is designed based on user experience. Our products are produced according to European Norm standards and have a CE certificate for international circulation. Our production facility is designed according to ISO 9001 standards. Our devices are guaranteed against production-related issues for 4 years. After 4 years, for refilling fire extinguishers, please contact our company.